Related Experiment Video
Updated: Aug 29, 2026

Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
Reflectance confocal microscopy may differentiate acute allergic and irritant contact dermatitis in vivo
Kirsty Swindells1, Nadine Burnett, Francisca Rius-Diaz
1Wellman Laboratories of Photomedicine, Massachusetts Geneeral Hospital, Harvard Medical School, Boston, Massachusetts 02114, USA.
Background:
Acute irritant contact dermatitis (ICD) and allergic contact dermatitis (ACD) may be difficult to distinguish by clinical or histologic assessment. Reflectance confocal microscopy (RCM) enables real-time, high-resolution skin imaging in vivo.
Objective:
We sought to image, characterize, and distinguish acute ACD and ICD in vivo.
Methods:
Volunteers with ACD were patch tested with an allergen and the irritant, sodium lauryl sulfate. RCM imaging and transepidermal water loss measurements were performed at 24 and 72 hours. Biopsy specimens were correlated with RCM images.
Results:
Spongiosis, epidermal inflammatory cell infiltrate, and vesicle formation were observed in ACD and ICD. Compared with ACD, ICD showed greater disruption of the stratum corneum, and more parakeratosis. There was a significantly greater increase in transepidermal water loss for ICD compared with ACD.
Conclusion:
RCM is a promising tool for dynamic, noninvasive assessment and may help to differentiate acute ACD and sodium lauryl sulfate-induced ICD.
More Related Videos
Related Concept Videos
Confocal Fluorescence Microscopy
Three-Dimensional Microscopy in Microbiology