Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Determination of phosphorous and sulfur in environmental samples by electrothermal vaporization inductively coupled
Yasuaki Okamoto1, Kouichirou Kanda, Satoru Kishiwada
1Department of Chemistry, Graduate School of Science, Hiroshima University, Kagamnivama, Higashihiroshima, 739-8526, Japan. yasuaki.okamoto@sci.hiroshima-u.ac.jp
Abstract:
From the viewpoint of selective introduction of the analyte from its solvent and matrices, electrothermal vaporization (ETV) is useful for the sample introduction into the inductively coupled plasma (ICP). By using a tungsten boat furnace (TBF) vaporizer system, the loss of analyte phosphorus, which normally occurs during the drying and ashing stages, is suppressed. The phosphate ion is reacted with the tungsten supplied from the surface of the TBF to form stable tungsten phosphate species. Regarding the determination of sulfur, additional chemical modifiers such as copper(II), lead(II), etc., are necessary to retain the analyte on the TBF. The furnace-fusion (FF) method or wet-digestion technique on the TBF is applied to unify the chemical forms of the analytes. Various oxidative and reductive inorganic compounds as well as organic compounds of phosphorus and sulfur show the same sensitivities after the FF digestion with hydrogen peroxide. The detection limits are 1.5 ng and 0.12 ng for phosphorous and sulfur, respectively. The repeatabilities in terms of the relative standard deviations of 10 replicate measurements of phosphorus and sulfur are 4.2% and 2.0%, respectively. Finally, the established method is applied to the determination of several environmental waters.
More Related Videos
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
Published on: May 18, 2018
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
Related Concept Videos
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography: Types of Detectors-II
Atomic Emission Spectroscopy: Instrumentation
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.