Reference distributions for complement proteins C3 and C4: a comparison of a large cohort to the world's literature
Robert F Ritchie1, Glenn E Palomaki, Louis M Neveux
1Foundation for Blood Research, Scarborough, Maine 04074, USA. ritchie@fbr.org
Insights
Establishing reliable reference intervals for serum complement proteins C3 and C4 is crucial for clinical use. This meta-analysis supports lifelong reference ranges, overcoming a key barrier in diagnosis and prognosis.
Area of Science:
- Clinical Chemistry
- Immunology
- Biomarker Discovery
Background:
- Serum complement protein (C3 and C4) measurements are vital for diagnosis and prognosis.
- Current limitations in bedside use stem from a lack of credible reference materials and quantification methods.
- Technological advancements have improved measurement capabilities, but reliable reference intervals across all ages remain a challenge.
Purpose of the Study:
- To establish reliable, lifelong reference intervals for serum complement proteins C3 and C4 for both males and females.
- To address the remaining barrier to cost-effective and relevant clinical use of serum protein data.
- To provide a robust dataset supporting the use of established reference ranges in clinical practice.
Main Methods:
- A meta-analysis of 51 publications reporting reference intervals for C3 and C4.
- Statistical analysis of identified reference intervals meeting predefined criteria from prior studies.
- Comparison of newly analyzed lifelong reference ranges with findings from previous smaller studies.
Main Results:
- The meta-analysis statistically analyzed data from 51 publications.
- Established lifelong reference ranges were found to agree with previous smaller studies.
- The findings provide strong support for the proposed reference ranges.
Conclusions:
- The study provides validated, lifelong reference intervals for serum C3 and C4.
- These reference intervals are essential for accurate diagnosis and prognosis across all age groups.
- The findings facilitate more relevant and cost-effective clinical application of complement protein testing.
Abstract:
The lack of credible reference materials and satisfactory methods for quantifying serum levels has limited the bedside use of complement protein (C3 and C4) measurements. However, great technological strides have been made in the last few years. The remaining barrier to a more relevant and cost-effective use of serum protein data for diagnosis and prognosis is the availability of reliable reference intervals from birth to old age for both males and females. Fifty-one publications reporting reference intervals were identified that meet the criteria used in our prior four studies, and these were analyzed statistically. Previous small studies with constrained age ranges agree, on average, with our larger series of life-long reference ranges. This meta-analysis provides support for our reference ranges and places them in the context of previous publications.
More Related Videos
07:26High-resolution Melting PCR for Complement Receptor 1 Length Polymorphism Genotyping: An Innovative Tool for Alzheimer's Disease Gene Susceptibility Assessment
Published on: July 18, 2017
06:29Methods for Quantitative Detection of Antibody-induced Complement Activation on Red Blood Cells
Published on: January 29, 2014
Related Concept Videos
Gene Families
Occasionally these regions can be adapted to take on new roles within the organism, becoming novel genes...
Immunoprecipitation
Chromatin Immunoprecipitation
Chromatin immunoprecipitation, also known as ChIP, is used to study protein-DNA or...