Related Experiment Video
Updated: Aug 29, 2026

Electrocardiogram Recordings in Anesthetized Mice using Lead II
Published on: June 20, 2020
Electrocardiographic identification of drug-induced QT prolongation: assessment by different recording and
Nenad Sarapa1, Joel Morganroth, Jean-Philippe Couderc
1Clinical Pharmacology, Pharmacia Corp., Kalamazoo, Michigan, USA. nenad.sarapa@pfizer.com
Background:
Careful assessment of QT interval prolongation is required before novel drugs are approved by regulatory authorities. The choice of the most appropriate method of electrocardiogram (ECG) acquisition and QT/RR interval measurement in clinical trials requires better understanding of the differences among currently available approaches. This study compared standard and Holter-derived 12-lead ECGs for utility in detecting sotalol-induced QT/QTc and RR changes. Manual methods (digitizing pad and digital on-screen calipers) were compared for precision of QT and RR interval measurement.
Methods And Results:
Sixteen hundred pairs of serial 12-lead digital ECGs were recorded simultaneously by standard resting ECG device and by continuous 12-lead digital Holter over 3 days in 39 healthy male and female volunteers. No therapy was given on the 1st day followed by 160 mg and 320 mg of sotalol on the 2nd and 3rd day, respectively. Holter-derived and standard ECGs produced nearly identical sotalol-induced QT/QTc and RR changes from baseline, as did the manual digipad and on-screen caliper measurements. The variability of on-screen QT measurement in this study was greater than that of digipad.
Conclusions:
Digital 12-lead Holter and standard 12-lead ECG recorders, as well as the manual digitizing pad and digital on-screen calipers, are of equal utility for the assessment of drug-induced change from baseline in QT and RR interval, although the variability of the on-screen method in this study was greater than of the digipad.
More Related Videos
08:28Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...