Continuous monitoring of oxygen consumption in patients undergoing weaning from mechanical ventilation
Keisuke Miwa1, Masahiro Mitsuoka, Shinzo Takamori
1Department of Surgery, Kurume University School of Medicine, 67 Asahi-machi, Fukuoka 830-0011, Japan. keisuke@med.kurume-u.ac.jp
Background:
The extubation or discontinuation of mechanical ventilatory support (MVS) is only the final step in the weaning process, and an improvement in the efficiency of the weaning process is required for more successful extubation or discontinuation of MVS.
Objective:
To evaluate whether continuous monitoring of oxygen consumption (VO2) using the metabolic gas monitor is a useful predictor of failure to tolerate a weaning trial of reduced MVS.
Method:
Twenty adult patients meeting the criteria for weaning, who required MVS > or = 7 days and who were previously deemed to have failed weaning by their attending physicians. A weaning trial was defined as a 30-min period during the strengthening training of our standardized weaning protocol. The average VO2, respiratory rate (RR), tidal volume (TV), minute ventilation (VE) and energy expenditure (EE) were recorded in respiratory muscles for a stable period of 20 min at rest and for the last 5 min of the trial. Subsequently, the oxygen cost of breathing (OCOB), the ratio of respiratory frequency to tidal volume (f/VT), DeltaRR, DeltaTV, DeltaVE, and DeltaEE were calculated.
Results:
Two hundred and eight weaning trials, including 145 successful trials and 63 failed trials from 20 patients were evaluated. In nonparametric analysis, a statistical difference in OCOB, DeltaRR, and DeltaEE was found between successful and failed weaning trials, while no statistical differences were found for the other parameters. An OCOB < 30% was the most accurate predictor of outcome of a weaning trial, and an f/VT < 105 was the least accurate. In a multiple logistic analysis, the OCOB revealed the highest odds ratio among all parameters.
Conclusions:
Measuring the OCOB was clinically beneficial in avoiding the induction of an excessive movement load on the respiratory muscles. In patients treated with MVS, continuous monitoring of VO2 is a useful to predict success or failure of trials attempting to reduce MVS.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)