Thoracic pedicle screw insertion using a transpedicular drill guide: a preliminary study
Related Experiment Video
Updated: Aug 29, 2026

Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model
Published on: May 24, 2024
J-M Mac-Thiong1, H Labelle, C-E Aubin
1Department of Orthopaedic Surgery, Université de Montréal, Montréal, Québec, Canada.
Abstract:
Insertion of thoracic pedicle screws can lead to major complications. This study reports the use of a transpedicular drill guide (TDG) for safe pedicle screw insertion in the thoracic spine. The conventional anatomic technique and the TDG were both used to drill pilot holes into the pedicles of four anatomic models of the thoracic spine. Ninety-nine percent of the 96 pilot holes drilled with the TDG were within 2 mm from the pedicle wall compared with 79% for the anatomic technique (P < 0.001). The TDG reduced the proportion and the extent of medial perforations. The TDG was easy to use and was superior to the conventional anatomic technique. It could be combined with fluoroscopy and pedicle palpation in certain clinical applications, especially for training surgeons, but only after confirming its accuracy in a cadaveric study.