Echocolor Power Doppler with contrast medium to evaluate vascularization in lesions of the soft tissues of the limbs
A De Marchi1, P De Petro, C Faletti
1Dipartimento di Radiologia, Dipartimento di Traumatologia ed Ortopedia, Azienda Ospedaliera CTO, CRF, Maria Adelaide, Torino.
Purpose:
Echocolor Power Doppler with contrast medium forms a non-invasive vascular image; the purpose of the study is to evaluate the effectiveness in differentiating benign and malignant tumors in the soft tissues of the limbs.
Material And Method:
Echocolor Power Doppler with contrast medium was used to study 80 patients with swelling in the soft tissues of the limbs: there were 54 benign lesions, 22 sarcomas, and 4 aggressive desmoid fibromatoses.
Results:
Were identified 4 patterns of wash-in and wash-out curves that could be correlated to the histological diagnosis: type I was present in 85% of benign lesions, type III in 91% of malignant lesions and in 3.7% of the benign ones, type II in aggressive fibromatoses, anomalous type in 4 benign lesions and 2 sarcomas; the curve was absent in 2 benign lesions.
Conclusions:
Power Doppler Echocolor with contrast medium can become a useful method to be associated with traditional imaging methods in the differential diagnosis of swelling of the soft tissues of the limbs.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...