Related Experiment Video
Updated: Aug 29, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Analysis of factors associated with variability in haemodialysis adequacy
Stewart H Lambie1, Maarten W Taal, Richard J Fluck
1Department of Renal Medicine, Derby City General Hospital, Derby, UK.
Background:
Delivered dialysis dose measured as Kt/V is widely accepted as an important factor affecting mortality on haemodialysis. It is currently measured relatively infrequently in most units for pragmatic reasons. We have previously shown that significant variation occurs within individuals which often makes the difference between dialysis that would be considered adequate, and inadequate. The aim of this study is to delineate which factors are responsible for the observed variation.
Methods:
We studied 1109 treatments in 109 patients, mean age 59.9 years, mean dry weight 71.8 kg. Depurated volume (Kt) was measured by ionic dialysance for each treatment. Kt and other relevant treatment-related variables were automatically recorded on a central server. Multivariate analysis using mixed models with backwards elimination was used to analyse the determinants of Kt. Kt/V was not used, in order to avoid introducing error in the determination of V.
Results:
The analysis indicated that the following were independent determinants of Kt: blood pump speed, time, minimum and mean arterial line pressure, both maximum and minimum venous line pressures and total ionic mass balance.
Conclusion:
This analysis suggests that the variation in adequacy that occurs within an individual is multifactorial. It confirms the importance of effective vascular access, prescription of and adherence to adequate time on dialysis, and reinforces the impact of degree of sodium removal. In clinical practice absolute control of these variables is not possible in every dialysis session and some degree of variability in Kt is therefore inevitable. Monitoring of adequacy thus requires more frequent assessment of Kt than is currently performed. Online monitoring of ionic dialysance achieves this.
Related Concept Videos
Hemodialysis III: Nursing Management
Hemodialysis II: Procedure and Complications
Hemodialysis I: Introduction
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...