Related Experiment Video
Updated: Aug 29, 2026

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
[Pulmonary mechanics, oxygenation index, and alveolar ventilation in patients with two controlled ventilatory modes.
Jorge A Castañón-González1, Marco Antonio León-Gutiérrez, Humberto Gallegos-Pérez
1Unidad de Cuidados Intensivos y Medicina Crítica, Hospital de Especialidades "Dr. Bernardo Sepúlveda Gutiérrez," Centro Médico Nacional Siglo XXI, IMSS, México, D.F. México. jorgec@prodigy.net.mx
Objective:
To compare in a crossover study pulmonary mechanics, oxigenation index (PaO(2)/FiO(2)), and partial pressure of CO(2) in arterial blood (PaCO(2)) in patients with mechanical ventilation in two controlled ventilatory modes.
Setting:
Intensive care unit of a university affiliated hospital.
Design:
Prospective crossover clinical trial.
Patients And Methods:
A total 114 consecutive patients were admitted to the intensive care unit (ICU) under controlled mechanical ventilation with SaO(2) >90% and FiO(2) <0.5 and assigned by random allocation to either volume control (VC) and constant inspiratory flow (square flow curve) (group I) or pressure control mode (PC) (group II). Both groups were ventilated with tidal volume (Vt) of 7 ml/kg, respiratory rate (RR) 14/min, inspiratory-expiratory ratio 1:2 (I:E), PEEP 5 cm H(2)O, and FiO(2) 0.4. After 15 min of mechanical ventilation, pulmonary mechanics, oxygenation index (OI), and PaCO(2) were measured and registered, and ventilatory mode was switched to PC mode in group I and to VC in group II, maintaining the same ventilator settings. Pulmonary mechanics, OI, and PaCO(2) were again registered after 15 min of ventilation.
Results:
Peak inspiratory pressure (PIP) was higher in VC than in PC (31.5 vs 26 cm H(2)O), which resulted in a significant increase in transpulmonary pressure amplitude difference (DP) (25 vs 19 cm H(2)O). Mean airway pressure (MAP) and OI were lower in VC than in PC (11.5 vs 12 cm H(2)O, and 198.5 vs 215, respectively). Dynamic compliance (DynC) was lower in VC than in PC (20 vs 26 ml/cm H(2)O), p < 0.05 for all values. At constant ventilator settings in the same patient, PC and not VC ventilation decreases PIP (which results in smaller transpulmonary pressure amplitude difference), increases MAP, and DynC and improves the oxygenation index.
More Related Videos
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Respiratory Volumes and Capacities