Related Experiment Video
Updated: Aug 29, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Detection of intracranial aneurysms with two-dimensional and three-dimensional multislice helical computed
Marko Kangasniemi1, Teppo Mäkelä, Seppo Koskinen
1Department of Radiology, Helsinki University Central Hospital, Helsinki, Finland. marko.kangasniemi@hus.fi
Objective:
Computed tomographic angiography (CTA) has become a diagnostic method for the detection of intracranial aneurysms in cases of subarachnoid bleeding. We sought to evaluate the detection of aneurysms with CTA with a novel multislice helical computed tomographic scanner.
Methods:
Prospectively, 179 patients underwent multislice CTA, followed by digital subtraction angiography (DSA) of both carotid arteries with or without the posterior circulation, DSA of one carotid artery with or without the posterior circulation, or DSA of the posterior circulation alone. The total number of carotid arteries studied was 298, and the number of vertebrobasilar arteries studied was 124.
Results:
Of 178 aneurysms verified with DSA or intraoperatively, CTA failed to detect 7 aneurysms of 1 to 2 mm and 1 partially thrombosed, 4-mm aneurysm. The sensitivity and specificity of CTA for aneurysm detection were 0.96 and 0.97, respectively.
Conclusion:
The first generation of multislice computed tomographic technology does not improve CTA to surpass DSA for the detection of small aneurysms of 1 to 2 mm. In practice, however, CTA is superior as a fast noninvasive method without complications.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...