Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
[Conventional ultrasonography Doppler in the assessment of arterial peripheral circulation]
P Rossi1, L Tauzin, A Boussuges
1Laboratoire de physiologie et action thérapeutique des gaz sous pression, faculté de médecine Nord, Chemin-des-Bourrely, Marseille, France. pascalrossi@yahoo.com
Unlabelled:
Ultrasonography Doppler in the assessment of arterial peripheral circulation.
Purpose:
The ultrasonography-Doppler study of peripheral arterial circulation requires measurements of arterial area and arterial blood flow. The aim of this study was to assess their variabilities, intra- and interobserver.
Methods:
We studied brachial arterial circulation of 13 volunteers. Two experimented investigators carried out the examinations. Arterial blood pressure measurements were obtained at the level of the brachial artery of the left arm by means of a semi automated oscillometric device. The brachial artery was approached by ultrasound scan in semi-decubitus position, the arm in exterior rotation and abduction. Brachial artery cross-sectional areas were obtained by a transversal view with a depth of 4-15-cm upstream the antecubital fossa of the forearm. Cross sectional areas were measured at end diastole (SD) and end systole (SS). We measured maximal systolic and diastolic velocities (Vmax and Vmin), mean velocity (Vmoy) and velocity integral (ITV) of the blood flow. We deduced brachial output (D), resistance and pulsatility index (IR, IP), cross-sectional compliance coefficient (C).
Results:
Intra- and interoperator variability as assessed by the Bland-Altman approach was acceptable SS, SD, ITV, D, Vmax, Vmoy, Vmin C, IR, and IP, in regard with values of variation coefficient, biais, and concordance limits.
Conclusion:
Conventional B-mode ultrasonography may offer a reliable method for arterial peripheral circulation evaluation.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation