Related Experiment Video
Updated: Aug 29, 2026

The Perinatal Asphyxiated Lamb Model: A Model for Newborn Resuscitation
Published on: August 15, 2018
The influence of vacuum extractor on fetal oxygenation and newborn status
Emmanouil Salamalekis1, Nikolaos Vitoratos, Dimitrios Kassanos
12nd Department of Obstetrics and Gynecology, University of Athens Aretaieion Hospital, 30 Roumelis Street, 152 33 Chalandri, Athens, Greece. deptobgyn@attikonhospital.gr
Aim:
The aim of this study was to determine the effects of vacuum extractor assisted delivery on fetal oxygenation and acid-base balance.
Methods:
Sixty-one women were enrolled in the present study. The subjects were divided into two groups. Group A, consisting of 39 women, had normal vaginal deliveries. Group B, consisting of 22 women, underwent a vacuum extractor assisted vaginal delivery. Fetal arterial oxygen saturation (SpO2) monitoring was used in all women after full cervical dilatation. After delivery, umbilical artery pH, pCO2, pO2 and base deficit (BDecf) levels were determined in all neonates.
Results:
The mean FSpO2 value in Group A was 51.53+/-5.87% and in Group B 48.03+/-6.39% (p<0.03). The mean cord pH value in fetuses of Group A was 7.26+/-0.05, and in Group B 7.17+/-0.09. There was also a significant difference between the two groups with regards to mean pO2, pCO2 and BDecf values.
Conclusions:
Vacuum assisted vaginal delivery was associated with lower fetal arterial oxygen saturation levels as well as lower cord blood pH values compared to those seen after unassisted vaginal delivery. Although decreased, however, the above parameters remained within normal ranges.
More Related Videos
05:40Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
10:55A Piglet Perinatal Asphyxia Model to Study Cardiac Injury and Hemodynamics after Cardiac Arrest, Resuscitation, and the Return of Spontaneous Circulation
Published on: January 13, 2023
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: