Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
The relationship between systemic and whole-body hematocrit is not constant during ultrafiltration on hemodialysis
Sandip Mitra1, Paul Chamney, Roger Greenwood
1Manchester Royal Infirmary, Manchester, United Kingdom.
The measurement of relative blood volume (RBV) changes during ultrafiltration assume a constant mass and distribution of circulating blood components such as hematocrit. The authors examine the validity of this assumption in 10 subjects undergoing repeated direct measurements of systemic hematocrit and plasma volume (PV(icg)) using indocyanine green dilution at four stages of dialysis with intermittent ultrafiltration. Ultrasonic RBV changes were monitored. Absolute blood volumes (ABV) were initially derived for each PV(icg) estimate, and corresponding measured systemic hematocrit was adjusted by a factor of 0.86 to correct for the difference between the systemic and whole-body hematocrit (constant Fcell ratio). PV(icg) and ABV changes correlated closely (R = 0.98; P <0.001). ABV changes overestimated reduction in PV(icg) during ultrafiltration (mean difference, -140 +/- 202 ml). The calculated red cell mass however was variable (P <0.01). Fcell ratio was then adjusted at each blood volume measurement (Fcell(1), 0.87 +/- 0.02; Fcell(2), 0.89 +/- 0.03; Fcell(3), 0.94 +/- 0.06; Fcell(4), 0.94 +/- 0.04; P <0.01) to maintain a constant red cell mass (2146 +/- 460 ml). When ABV was recalculated using PV(icg), systemic hematocrit and variable Fcell (ABV(Fvariable)), the mean difference between PV(icg) changes and ABV(Fvariable) changes, was negligible (-0.2 +/- 35 ml). During intermittent ultrafiltration, RBV changes systematically underestimated the percentage reduction in ABV (mean difference, 7.7 +/- 10.6%). When corrected for variations in Fcell, ABV(Fvariable) and RBV differences were negligible (mean difference 1.2 +/- 2.6%). Varying Fcell ratio probably reflects microvascular volume change with net fluid shift from the microcirculation to macrocirculation (intravascular refill). This may result in underestimation of changes in systemic hematocrit and RBV during dialysis such that they were less than those predicted by directly measured changes in plasma volume.
The measurement of relative blood volume (RBV) changes during ultrafiltration assume a constant mass and distribution of circulating blood components such as hematocrit. The authors examine the validity of this assumption in 10 subjects undergoing repeated direct measurements of systemic hematocrit and plasma volume (PV(icg)) using indocyanine green dilution at four stages of dialysis with intermittent ultrafiltration. Ultrasonic RBV changes were monitored. Absolute blood volumes (ABV) were initially derived for each PV(icg) estimate, and corresponding measured systemic hematocrit was adjusted by a factor of 0.86 to correct for the difference between the systemic and whole-body hematocrit (constant Fcell ratio). PV(icg) and ABV changes correlated closely (R = 0.98; P <0.001). ABV changes overestimated reduction in PV(icg) during ultrafiltration (mean difference, -140 +/- 202 ml). The calculated red cell mass however was variable (P <0.01). Fcell ratio was then adjusted at each blood volume measurement (Fcell(1), 0.87 +/- 0.02; Fcell(2), 0.89 +/- 0.03; Fcell(3), 0.94 +/- 0.06; Fcell(4), 0.94 +/- 0.04; P <0.01) to maintain a constant red cell mass (2146 +/- 460 ml). When ABV was recalculated using PV(icg), systemic hematocrit and variable Fcell (ABV(Fvariable)), the mean difference between PV(icg) changes and ABV(Fvariable) changes, was negligible (-0.2 +/- 35 ml). During intermittent ultrafiltration, RBV changes systematically underestimated the percentage reduction in ABV (mean difference, 7.7 +/- 10.6%). When corrected for variations in Fcell, ABV(Fvariable) and RBV differences were negligible (mean difference 1.2 +/- 2.6%). Varying Fcell ratio probably reflects microvascular volume change with net fluid shift from the microcirculation to macrocirculation (intravascular refill). This may result in underestimation of changes in systemic hematocrit and RBV during dialysis such that they were less than those predicted by directly measured changes in plasma volume.
Related Concept Videos
Dialysis
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration
Continuous Renal Replacement Therapy
Hemodialysis I: Introduction