Pheochromocytomas: detection with 11C hydroxyephedrine PET
Carlos Trampal1, Henry Engler, Claes Juhlin
1Uppsala University PET Centre, Sweden and Surgery Department, University Hospital, Uppsala, Sweden. ctrampal@frs.seris.es
Purpose:
To evaluate the accuracy of carbon 11 (11C) hydroxyephedrine (HED) positron emission tomography (PET) in the detection of pheochromocytomas.
Materials And Methods:
Nineteen patients (12 women, seven men; mean age, 53 years) suspected of having pheochromocytoma were evaluated. Patients had enlarged adrenal glands at computed tomography and either increased urinary catecholamine levels (n = 18) or normal biochemistry (n = 1). Dynamic PET examination in the adrenal region was performed after injection of 800 MBq 11C HED. PET data were analyzed visually and semiquantitatively. Time-activity curves were generated for different organs. PET results were validated with histologic evaluation (n = 16) or clinical follow-up (n = 3). The diagnostic value of HED PET was evaluated by calculating the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy.
Results:
In 12 patients, 13 pheochromocytomas were verified at surgery and histologic evaluation. All but one of the pheochromocytomas were detected with HED PET, which demonstrated elevated uptake. The rest of the patients (n = 7) did not have pheochromocytomas. In these patients, HED PET did not show any abnormal uptake in the suspicious tumors (confirmed at surgery in four patients and at clinical follow-up in three). Mean standardized uptake value of the tumors was 21.4 (range, 11.1-40.9). The time-activity curves for pheochromocytomas showed early uptake after injection, and the activity increased with the time of examination. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of HED PET in the detection of pheochromocytomas were 92% (12 of 13), 100% (seven of seven), 100% (12 of 12), 87.5% (seven of eight), and 95% (19 of 20), respectively.
Conclusion:
HED PET is useful in the detection of pheochromocytomas, providing a high level of accuracy.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET