Related Experiment Videos
[Systemic-pulmonary shunt with autologous internal jugular vein]
P Martínez Corrales1, A Cabrera, A del Campo
1Servicio de Cirugía Cardíaca, Hospital Infantil de Cruces, Vizcaya.
Revista Espanola De Cardiologia
|November 1, 1992
Abstract:
We report a variant of systemic-pulmonary shunt for newborns or low-weight neonates affected with hypoplasia or atresia of pulmonary artery. An autologous internal jugular vein was used. Six months after surgery all patients referred no symptoms and a normal systemic-pulmonary shunt with an arterial oxygenation of 82-90% was present.