Related Experiment Video
Updated: Aug 29, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Effectiveness of customised neutron shielding in the maze of radiotherapy accelerators
E J Waller1, T J Jamieson, D Cole
1SAIC Canada, 60 Queen Street, Suite 1516 Ottawa, Ontario, Canada K1P 5Y7. edward.j.waller@saic.com
Abstract:
An investigation was performed to examine the neutron dose equivalent in a radiotherapy maze lined with a customised neutron shielding material. The accelerator investigated was a Varian Clinac 2100C/D using 18 MV photons, and the neutron shielding utilised at this centre was Premadex commercially available neutron shielding. Based on Monte Carlo simulations, properly installed customised neutron shielding may reduce the neutron dose equivalent by up to a factor of 8 outside the maze, depending upon the installation. In addition, it was determined that the neutron dose near the entrance to the maze may be reduced by approximately 40% by using customised neutron shielding in the maze, as compared with a facility not using this shielding. This would have a positive dose-saving effect in doorless maze designs.
More Related Videos
05:18Radiation Planning Assistant - A Web-based Tool to Support High-quality Radiotherapy in Clinics with Limited Resources
Published on: October 6, 2023
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Diamagnetic Shielding of Nuclei: Local Diamagnetic Current
Biological Effects of Radiation