Measurement of respiratory function by impulse oscillometry in horses
1Laboratory for Functional Investigation, Department of Physiology, Faculty of Veterinary Medicine, University of Liège, Liège, Belgium.
Equine Veterinary Journal
|February 6, 2004
Summary
Impulse oscillometry (IOS) offers a repeatable and informative method for equine pulmonary function testing. This technique is valuable for diagnosing respiratory conditions like heaves in horses.
Area of Science:
- Equine respiratory physiology
- Pulmonary function testing
- Forced oscillation technique
Background:
- Traditional pulmonary function tests have limited clinical use due to technical challenges and low sensitivity.
- Impulse oscillometry (IOS) presents a viable alternative for assessing respiratory function.
Purpose of the Study:
- To establish the feasibility, methodology, and repeatability of IOS in horses.
- To define reference values for respiratory resistance (Rrs) and reactance (Xrs) using IOS.
- To investigate the influence of biometrical parameters and compare IOS in healthy vs. heaves-affected horses.
Main Methods:
- IOS was performed on 38 healthy horses to establish reference values for Rrs and Xrs.
- Methodology focused on ensuring facemask airtightness, minimal dead space, and standardized head positioning.
- IOS measurements were compared between 6 healthy horses and 6 horses with clinical signs of heaves.
Main Results:
- Airtight facemasks and standardized head position were crucial for accurate IOS measurements.
- IOS measurements demonstrated repeatability in both healthy and diseased horses.
- Specific IOS parameters (increased R5Hz, R5Hz>R10Hz, and negative Xrs) indicated heaves crisis in affected horses.
Conclusions:
- Impulse oscillometry is a quick, minimally invasive, and informative pulmonary function test for horses.
- IOS shows promise for routine and field-based respiratory clinical assessments in equine practice.