The purpose of this study is to examine clinical progress and hemodynamic and electrocardiologic features (QT depression and heart rate variability [HRV]) of patients exposed to a scorpion bite. Seventeen patients bitten by scorpions, and, as a control group, 15 healthy subjects were included in the study. Standard electrocardiograph (ECG) records, 24-hour Holter-ECG, and Doppler echocardiographic examinations were performed. Holter ECG indicated sinus tachycardia, sinus bradycardia, paroxysmal supraventricular tachycardia, atrial fibrillation, first-degree and second-degree atrioventricular block not requiring treatment, early atrial beats, and early ventricular beats in the patients at frequencies of 82%, 12%, 35%, 12%, 8%, 70%, and 47%, respectively. HRV parameters that reflected parasympathetic activity (SD 35+/-13-43+/-16, RMS-SD: 20+/-9-30+/-12, high frequency: 7.8+/-2-4.3+/-3, p<0.05) were significantly lower (p<0.05). Low frequency, which especially showed sympathetic activity (LF: 11+/-13-11+/-23, p>0.05), was similar in both groups. In addition, the LF/HF ratio, which reflected sympathovagal balance, was significantly increased in the patient group (1.5+/-1-3.0+/-2, p=0.005). Corrected QT and QT dispersion values were not significantly different with respect to the control (p>0.05). In the patient group compared to the control, a significant decrease was determined in the proportion of mitral E velocity to mitral A velocity (mEv/mAv), diastolic filling period (DFP), and left ventricular ejection fraction (LVEF), while a significant increase was noticed in pulmonary artery pressure (PAP) (mEv/mAv: 0.9+/-0.4-1.7+/-0.6, DFP: 362+/-8.5-425+/-89, LVEF: 53.1+/-6.7-68.6+/-5.8, PAP: 38.1+/-13-27.2+/-6, p<0.05). Scorpion bite leads to serious cardiovascular disorders, associated with decreased HRV, decreased systolic and diastolic functions, increased arrhythmic events, and hemodynamic disturbance with sympathetic and parasympathetic balance disturbance.
More Related Videos
08:28Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Aortic Regurgitation II: Clinical Features and Diagnostic Tests