Related Experiment Video
Updated: Aug 29, 2026

High-Pressure NMR Experiments for Detecting Protein Low-Lying Conformational States
Published on: June 29, 2021
Thermodynamic studies of pressure-induced retention of peptides in reversed-phase liquid chromatography
1Department of Chemistry, National Cheng Kung University, Tainan 701, Taiwan. shchen@mail.ncku.edu.tw
Abstract:
The pressure-induced retention of peptides on reversed-phase HPLC was studied by systematically changing organic solvent composition and temperature at both low (19 bar) and high (318 bar) pressures using a homologous series of hydrophobic poly-L-phenylalanine (n = 2-7) as the model compound. Based on van' t Hoff plots under different organic solvent compositions and pressures, the enthalpy change for the solute (deltaH) was determined. Moreover, both the enthalpy and entropy change for each phenylalanine residue (deltadeltaH and deltadeltaS), which corresponds to solute retention on a microenvironment along the depth of C18 chain, were also calculated by direct subtractions. Results indicate that under acetonitrile (ACN) compositions above 35%, the pressure caused deltadeltaS value to change from a negative to a positive value and both deltaH and deltadeltaH to change from a negative to a less negative value, all leading to a thermodynamic state closer to those under 35% acetonitrile composition. This implies that the pressure-induced retention observed in this study was an entropy-favored but enthalpy-unfavored process and was explained by pressure-induced desorption of solvent molecules that were associated with the stationary phase or with the peptide solute. Under 35% acetonitrile composition, however, it was found that neither deltadeltaH nor deltadeltaS value was significantly changed by the pressure. Whereas, both deltaH value and the intercept of van't Hoff plots under 35% acetonitrile composition were increased by pressure. This indicates that under low organic solvent composition, 35%, most of the acetonitrile molecules adsorbed on the surface of the stationary phase and only little solvent molecules were dissolved in the bulk stationary phase where the phenylalanine residues were partitioned. This study has provided new thermodynamic insights to the pressure-induced retention for peptides and proteins.
Related Concept Videos
Chromatographic Methods: Terminology
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Free Energy and Equilibrium
Recall that Q is the numerical value of the mass action expression...