Ultrasound versus computed tomography in the imaging of orbital floor fractures
Siegfried Jank1, Rüdiger Emshoff, Monika Etzelsdorfer
1Department of Oral and Maxillofacial Surgery, University of Insbruck, Inssdbruck, Austria. siegfried.jank@gmx.de
Purpose:
The aim of the study was to investigate whether orbital ultrasonography (US) with a curved-array transducer could be an alternative imaging method to computed tomography (CT) to detect orbital wall fractures and fractures of the infraorbital rim.
Materials And Methods:
Fifty-eight patients with the clinical ophthalmologic or radiologic diagnosis of an orbital trauma were investigated prospectively by US and CT. The reference method was the intraoperative findings.
Results:
CT evaluation of the infraorbital rim yielded a sensitivity of 79%, a specificity of 90%, and an accuracy of 94%. The positive predictive value (PPV) and the negative predictive value (NPV) of the infraorbital rim reached 69% and 83%, respectively. CT evaluation of the orbital floor showed a sensitivity of 96%, a specificity of 71%, and an accuracy of 96%. PPV and NPV resulted in 71% and 93%, respectively. US investigation of the infraorbital rim yielded a sensitivity of 77%, a specificity of 89%, and an accuracy of 97%, whereas PPV and NPV reached 65% and 83%, respectively. US investigation of the orbital floor reached a sensitivity of 94%, a specificity of 57%, and an accuracy of 96%, whereas PPV and NPV yielded 57% and 91%, respectively. No significant difference was found between US and CT in the investigation of the infraorbital rim (P =.809) and the orbital floor (P =.729).
Conclusions:
US with a curved-array transducer appears to be a useful alternative method in the investigation of orbital floor fractures. Further studies have to be conducted to reduce the presence of false-negative results.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...