Influence of calibration methodology on ground water flow predictions
James E Saiers1, David P Genereux, Carl H Bolster
1School of Forestry and Environmental Studies, Yale University, New Haven, CT 06511, USA. james.saiers@yale.edu
Abstract:
We constructed a numerical model of transient ground water flow and solute transport for a portion of the Biscayne Aquifer in Florida, and calibrated the model with three different combinations of data from a 193-day period: head (h) data alone, data on h and ground water discharge to a canal (q), and data on h, q, and ground water chloride concentration (C). We used each of the three calibrated models to predict h and q during a 182-day test period separate from the calibration period. All three calibrated models predicted h equally well during the test period (r = 0.95, where r = 1 indicates perfect agreement between measured and simulated values), though the model calibrated on h alone had significantly different parameter values than the other two models. Predictions of q during the test period depended on calibration methodology; models calibrated with multiple targets simulated q more accurately than the model calibrated on h alone (r = 0.79 compared to r = 0.49). Based on the results of these simulations, we conclude: (1) Post-calibration prediction is important in assessing the value of different data types in automated calibration; (2) inverse-solution uniqueness is not a requirement for accurate h predictions; (3) relatively simple models can predict with reasonable accuracy transient ground water flow in a complex aquifer, and parameters governing this prediction can be estimated by nonlinear regression methods that incorporate both h and q data; (4) addition of C data to the calibration did not improve model predictive capacity because the information in the C data was similar to that in the q data, from the perspective of model calibration (the subsurface chemical signal in question was controlled mainly by seepage of high-chloride canal water into the low-chloride ground water system).
More Related Videos
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Typical Model Studies
Design Example: Creating a Hydraulic Model of a Dam Spillway
Gradually Varying Flow


