Electrothermal atomic absorption spectrometric-determination of cobalt in human serum and urine
Nadica Todorovska1, Irina Karadjova, Sonja Arpadjan
1Institute of Preventive Medical Care and Toxicology, Military Health Institution Center, 1000 Skopje, Macedonia.
Abstract:
Problems and possibilities of the determination of Co in serum and urine samples by electrothermal atomic absorption spectrometry (ETAAS) are described. Optimal instrumental parameters as well as a suitable atomizer, calibration procedure and hydrogen peroxide as modifier are proposed for direct ETAAS measurement of Co in serum and urine. The detection limit achieved was 0.1 microg L(-1) for both matrices and relative standard deviations varied in the range 5-20% depending on the Co concentration in the sample. Validity of the method was verified by the analyses of standard reference materials. For serum samples with a Co content lower than the detection limit, a separation and preconcentration procedure based on liquid/liquid extraction is suggested prior to determination of Co in the organic phase by ETAAS. This procedure permits determination of 0.02 microg L(-1) Co in serum samples with a relative standard deviation of 10-18%.
More Related Videos
05:08Measurement of Tissue Non-Heme Iron Content using a Bathophenanthroline-Based Colorimetric Assay
Published on: January 31, 2022
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Overview
Coulometry: Overview
Controlled-Current Coulometry: Overview
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...