Related Experiment Video
Updated: Aug 13, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
[The John Sutton Lecture: CSEP, 2002]. Pulmonary system limitations to exercise in health
Jerome A Dempsey1, A William Sheel, Hans C Haverkamp
1Dept. of Population Health Sciences, John Rankin Laboratory of Pulmonary Medicine, University of Wisconsin-Madison, Madison, WI 53705, USA.
Abstract:
It is commonly held that the structural capacity of the normal lung is "overbuilt" and exceeds the demand for pulmonary O2 and CO2 transport in the healthy, exercising human. On the other hand, the adaptability of pulmonary system structures to habitual physical training is substantially less than are other links in the O2 transport system. Accordingly, in some highly fit, and even in some not so fit habitually active individuals, the lung's diffusion surface, airways, and/or chest-wall musculature are underbuilt relative to the demand for maximal O2 transport. Two specific pulmonary limitations to exercise performance are proposed: (1) exercise-induced arterial hypoxemia secondary to excessive widening of the alveolar to arterial O2 difference, inadequate hyperventilation, and metabolic acidosis; and (2) highly fatiguing levels of respiratory muscle work which effectively steals blood flow from locomotor muscles via sympathetically mediated reflexes and heightens the perception of limb discomfort and dyspnea. In this brief review, we describe the characteristics and causes of each of these proposed pulmonary limitations and their consequences to maximal O2 uptake and exercise performance.
More Related Videos
Related Concept Videos
Lung Capacity
Respiratory Volumes and Capacities I
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Pulmonary Edema II: Pathophysiology

