Related Experiment Video
Updated: Aug 10, 2026

Testing Tactile Masking between the Forearms
Published on: February 10, 2016
Two experiments on the spectral boundary conditions for nonlinear additivity of simultaneous masking
L E Humes1, L W Lee, W Jesteadt
1Department of Speech and Hearing Sciences, Indiana University, Bloomington 47405.
Abstract:
The present paper describes the results from two experiments which explored the spectral boundaries for the nonlinear additivity of simultaneous masking. The first experiment measured the threshold for detection of a 2-kHz tone in the presence of two 800-Hz-wide bands of noise that had varying degrees of spectral overlap with each other and the 2-kHz signal. Results revealed an abrupt transition from linear to nonlinear additivity of masking as the spectral separation between the two maskers varied from some overlap to none. The second experiment examined alternative explanations for the data. Explanations based on restricted-listening or distortion-product-detection hypotheses were not supported by the results of this experiment. These data indicate that nonlinear additivity of simultaneous masking holds for maskers that do not overlap within the critical band centered on the signal frequency. This interpretation is also consistent with a large body of data on the monaural and binaural summation (additivity) of loudness.
Related Concept Videos
Interference and Diffraction
Interference and Superposition of Waves
Interference occurs in mechanical waves, such as sound waves, waves on a string, and surface water waves. Mechanical waves correspond to the physical displacement of particles. Hence,...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Boundary Conditions: Lossless Lines
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...