Related Experiment Videos
Determination of eperisone in human plasma by gas chromatography-mass spectrometry
T Takamatsu1, K Yamazaki, M Kayano
1Department of Clinical Chemistry, Tokyo Research Laboratories, Eisai Co., Ltd., Tokyo, Japan.
Abstract:
A gas chromatographic-mass spectrometric method was developed to determine eperisone hydrochloride, 4'-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride, in human plasma over the concentration range 0.2-40 ng/ml. Excellent sensitivity was achieved by selection of a favorable fragment ion, m/z 98, of eperisone and reduction of heat decomposition of eperisone by using a splitless injector and a shortened capillary column. The method described here allows the determination of plasma concentrations as low as 0.2 ng/ml, the concentration attained 6 h after a single oral administration of 50 mg. At eperisone hydrochloride concentrations higher than 0.5 ng/ml, the mean inter-day variation of accuracy of the assay was less than 12%.