Related Experiment Video
Updated: Aug 2, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Ambulatory oxygen uptake measurement system
1Department of Electrical and Electronic Engineering, Yamaguchi University, Japan.
Abstract:
An apparatus for monitoring prolonged measurement of oxygen uptake without discomfort has been developed. The system is based on the open flow-through principle. The subject wears a hood through which air is drawn by an exhaust blower. Oxygen concentration is kept constant by a servo-controlled blower, so that flow rate is essentially proportional to oxygen uptake. The flow rate of the main stream is measured by a time-of-flight flowmeter located in the exhaust hose. Oxygen concentration is measured by a limiting-current oxygen sensor. The signals representing flow rate and oxygen concentration are digitized and stored in a memory. All of the equipment is assembled in a small package (wt = 3 kg) which the subject carries on his back. The memory chip is removed from the portable device after each experiment. Data are transferred from the memory to a microcomputer and then an oxygen uptake trend is estimated. Response of the system to a step input is about 30 s. Compared with a commercially available oxygen monitoring system (Magna 88, P. K. Morgan Ltd., Rainham, UK), the maximum difference was 0.15 L/min within an oxygen uptake range of 0.25-2.3 L/min. Thus, the measurements made with our portable device agree with the results obtained using the conventional method.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...