Impedance cardiography using the Sramek-Bernstein method: accuracy and variability at rest and during exercise
1Division of Pharmacological Sciences and Toxicology, United Medical School, London.
British Journal of Clinical Pharmacology
|December 1, 1992
Summary
This study validates impedance cardiography for measuring cardiac output and timing. The non-invasive method shows good agreement with established techniques in healthy individuals and critically ill patients, offering reproducible semi-quantitative cardiac performance data.
Area of Science:
- Cardiology
- Biomedical Engineering
- Physiology
Background:
- Impedance cardiography (ICG) is a non-invasive technique for assessing cardiac function.
- Established methods for measuring stroke volume and systolic time intervals are often invasive or complex.
- A validated, simple, and inexpensive method for cardiac output measurement is needed.
Purpose of the Study:
- To evaluate the accuracy and reliability of Sramek and Bernstein's impedance cardiography method.
- To compare ICG measurements of stroke volume and systolic time intervals with established reference techniques.
- To assess the utility of ICG in healthy volunteers, critically ill patients, and patients with coronary heart disease.
Main Methods:
- Comparison of ICG measurements with mechanophonocardiography, thermodilution, and dye dilution techniques.
- Assessment of pre-ejection period (PEP), ventricular ejection time (VET), and their ratio (PEP/VET).
- Correlation of ICG-derived parameters with angiographic left ventricular ejection fraction in coronary heart disease patients.
Main Results:
- No significant bias and narrow limits of agreement for PEP, VET, and PEP/VET ratio in healthy volunteers compared to mechanophonocardiography.
- Moderate agreement for stroke volume measurements in critically ill patients (vs. thermodilution) and healthy volunteers (vs. dye dilution).
- Accurate detection of drug-induced stroke volume changes and correlation of ICG parameters with left ventricular ejection fraction (r = -0.81 to 0.65).
Conclusions:
- Impedance cardiography provides reproducible semi-quantitative measurements of cardiac performance and blood flow.
- The method demonstrates good agreement with established techniques in various patient populations.
- ICG is a valuable tool for pharmacodynamic measurements when invasive methods are not suitable.