Related Experiment Video
Updated: Aug 26, 2026

Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
18F-FLT PET for visualization of laryngeal cancer: comparison with 18F-FDG PET
David C P Cobben1, Bernard F A M van der Laan, Bram Maas
1PET Center, Groningen University Hospital, PO Box 30.001, 9700 RB Groningen, The Netherlands. D.C.P.Cobben@pet.azg.nl
Unlabelled:
The feasibility of (18)F-3'-fluoro-3'-deoxy-L-thymidine PET (FLT PET) for detecting laryngeal cancer was investigated and compared with (18)F-FDG PET.
Methods:
Eleven patients diagnosed with or strongly suspected of having recurrent laryngeal cancer and 10 patients with histologically proven primary laryngeal cancer underwent attenuation-corrected (18)F-FLT PET imaging 60 min after injection of a median of 213 MBq (range, 175-400 MBq) (18)F-FLT and attenuation-corrected (18)F-FDG PET imaging 90 min after injection of a median of 340 MBq (range, 165-650 MBq) (18)F-FDG. All patients were staged by endoscopy and CT according to the Union Internationale Contre la Cancer TNM staging system. All patients underwent biopsy of the laryngeal area after imaging. Lesions seen on (18)F-FDG PET and (18)F-FLT PET were compared with histopathologic results. Mean SUVs, maximum SUVs, and tumor-to-nontumor (TNT) ratios were calculated for (18)F-FLT and (18)F-FDG. Wilcoxon nonparametric testing was used for comparison of (18)F-FDG with (18)F-FLT uptake. The Spearman correlation coefficient was used to correlate mean SUVs, maximum SUVs, and TNT ratios of (18)F-FDG PET and (18)F-FLT PET. Two-tailed P values < 0.05 were considered significant.
Results:
(18)F-FDG PET and (18)F-FLT PET detected laryngeal cancer correctly in 15 of 17 patients. One lesion judged as positive on (18)F-FDG PET turned out to be normal tissue. Of 2 lesions judged as positive on (18)F-FLT PET, 1 turned out to be inflammation and the other to be normal tissue. Maximum SUVs were 3.3 (range, 1.9-8.5) for (18)F-FDG and 1.6 (range, 1.0-5.7) for (18)F-FLT (P < 0.001). Mean SUVs were 2.7 (range, 1.5-6.5) for (18)F-FDG and 1.2 (range, 0.8-3.8) for (18)F-FLT (P < 0.001). TNT was 1.9 (range, 1.3-4.7) for (18)F-FDG and 1.5 (range, 1.1-3.5) for (18)F-FLT (P < 0.05).
Conclusion:
The numbers of laryngeal cancers detected with (18)F-FLT PET and (18)F-FDG PET were equal. In laryngeal cancer, the uptake of (18)F-FDG is higher than that of (18)F-FLT.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET