Related Experiment Video
Updated: Aug 26, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Determination of trace cobalt concentrations in human serum by adsorptive stripping voltammetry
Petra Kajic1, Ingrid Milosev, Boris Pihlar
1Department of Physical and Organic Chemistry, Jozef Stefan Institute, Ljubljana, Slovenia.
Abstract:
The goal of our study was to develop an accurate and reliable method for determining trace cobalt concentrations in human serum. The method was used to determine cobalt in the sera of healthy persons and patients with orthopaedic implants containing cobalt - a possible source of systemic release of cobalt into the human body. This goal is of vital interest since cobalt and its compounds are classified by IARC as potentially carcinogenic to humans. We used an electrochemical method, adsorptive stripping voltammetry (AdSV), which made possible the low detection limit and high sensitivity needed for measurements in human serum. The serum was acid digested by a combination of H2SO4, HNO3 and H2O2 in a 10 mL Kjeldhal flask. The digested sample was then dissolved in 0.1 mol/L ammonia buffer, pH 9.0 +/- 0.2. The determination is based on the adsorptive collection of the complex of cobalt (II) with dimethylglyoxime on a hanging mercury drop electrode (HMDE). The optimum values of adsorption potential and time were determined to be -0.8 V and 60 s. The optimisation of the sample digestion protocol and measurement procedures ensured the reliable assessment of low cobalt concentrations, down to 0.03 microg/L. The mean concentration of serum cobalt in four healthy persons was 0.11 +/- 0.06 microg/L, and in four patients with total hip replacements 0.34 +/- 0.07 microg/L. This method will be used routinely for measuring serum cobalt levels in patients with total hip replacements.
More Related Videos
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Electrodeposition
Electrodeposition can...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Cyclic Voltammetry