Hydrophobic and cation exchange mechanisms in the retention of basic compounds in a polymeric column
Rebeca Ruiz1, Ma José Ruiz-Angel, Ma Celia García-Alvarez-Coque
1Departament de Química Analítica, Universitat de Barcelona, Diagonal 647, 08028 Barcelona, Spain.
Abstract:
A cation exchange retention mechanism concomitant with the well-known hydrophobic partition mechanism in a polymeric column has been observed and investigated. This exchange process is attributed to ionization of some acidic sites present in the polymer column at basic mobile phase pH values. Several drugs of different basicity have been chromatographed on a polymeric PLRP-S column with methanol-water and acetonitrile-water mobile phases. The cation exchange between the protonated basic drug and the buffer cations (Na+, K+ and BuNH4+) is observed at the pH range where the protonated drug and the ionized sites of the column coexist. This process produces a shift of the retention versus pH plot of the base to pH values lower than those expected from the pKa of the base as well as a maximum in the plot at basic pH values. These effects are more pronounced for acetonitrile-water mobile phases.
More Related Videos
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
Related Concept Videos
Ion Exchange
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Analyte Adsorption and Distribution
Pore Transport and Ion-Pair Transport
Pore transport, also known as convective transport, is a process where small molecules like urea, water, and sugars rapidly cross cell membranes as though there were channels or pores in the membrane. Although direct microscopic evidence is limited but the concept of pores or channels is widely accepted based on physiological evidence. Despite the lack of direct microscopic...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...