Related Experiment Video
Updated: Aug 26, 2026

Continuously-stirred Anaerobic Digester to Convert Organic Wastes into Biogas: System Setup and Basic Operation
Published on: July 13, 2012
Start-up of anaerobic ammonia oxidation bioreactor with nitrifying activated sludge
Ping Zheng1, Feng-mei Lin, Bao-lan Hu
1Department of Environmental Engineering, Zhejiang University, Hangzhou 310029, China. pzheng@zju.edu.cn
Abstract:
The anaerobic ammonia oxidation(Anammox) bioreactor was successfully started up with the nitrifying activated sludge. After anaerobically operated for 105 d, the bioreactor reached a good performance with removal percentage of both ammonia and nitrite higher than 95% and volumetric total nitrogen removal as high as 149.55 mmol/( L.d). The soft padding made an important contribution to the high efficiency and stability because it held a large amount of biomass in the bioreactor.
Related Concept Videos
Bioreactor Design and Operational System
Bioreactor Controls-II
Microbial Wastewater Treatment
Inorganic Nitrogen Assimilation
Biological Treatment of Effluent and Waste Water
Bioreactor Controls-I