Electrophoretic Separation of Proteins
Published on: June 12, 2008
Effect of sample composition on electrophoretic migration application to hemoglobin analysis by capillary
1Department of Pathology, Wake Forest University School of Medicine, Winston-Salem, NC 27157, USA. zshihabi@wfubmc.edu
Abstract:
The electrophoretic migration, in routine analysis, is crucial for compound identification especially when multiple components are present in the sample. In complex or crude samples, such as those obtained from biological fluids, electrophoretic migration often does not correspond well to that of a pure standard compound. Several factors, related to the sample itself, have been identified as modulating the electrophoretic migration in zone electrophoresis both in gel and capillary electrophoresis (CE): solute mobility and concentrations, salt content, and protein interaction in the sample. Peak shape asymmetry often signals changes in migration especially when comparing samples with wide differences in concentration or those containing high ionic strength. Also, the migration of a protein can be influenced by the presence of a high concentration of another slowly migrating protein in the sample. A weak interaction during the separation between the two proteins which lead to a decreased velocity has been postulated. This was confirmed by finding a curve-linear relationship between the ratio of the two hemoglobin (Hb) variants, hemoglobin F (Hb F) and hemoglobin S (Hb S), and the distance between the two in gel electrophoresis (GE); and also by the observation of formation of a new small peak based on the analysis of hemoglobin F by capillary electrophoresis upon the addition of Hb S to the separation buffer. These factors when present together have an additive effect on the migration. As an example, Hb F, present in low but variable concentration in patients with sickle cell disease (Hb S), migrates in gel electrophoresis slightly slower than it is expected; enough to be confused with other unknown variants. However, the small peaks with different migration distances between Hb S and the adult Hb (Hb A) correlated well (r = 0.98) with Hb F performed by an alkali-denaturing assay indicating that these peaks are indeed Hb F in spite of the difference in their migration.
Related Concept Videos
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...