Related Experiment Video
Updated: Aug 26, 2026

Surgical Porcine Model of Chronic Myocardial Ischemia Treated by Exosome-laden Collagen Patch and Off-pump Coronary Artery Bypass Graft
Published on: September 15, 2023
Cardiac output monitoring during off-pump coronary artery bypass grafting
Matthew P Grow1, Amrik Singh, Neal W Fleming
1Department of Anesthesiology, University of California Davis, Sacramento, CA 95817, USA.
Objective:
To evaluate and compare monitors of cardiac output during repositioning and stabilization of the heart for off-pump coronary artery bypass (OPCAB) surgery.
Design:
Prospective, observational, clinical study.
Setting:
University teaching hospital.
Participants:
Consecutive patients scheduled to undergo elective OPCAB (n = 19).
Interventions:
Monitoring, induction, and anesthesia followed a routine protocol for coronary artery bypass patients. This included the use of transesophageal echocardiography (TEE) and pulmonary artery catheter placement.
Measurements And Main Results:
After positioning and stabilization for OPCAB surgery, the changes in descending aortic flow velocity (VTI) times heart rate (HR) and the mixed venous oxygen saturation (SvO(2)) could be used to predict the changes in thermodilution cardiac output (TDCO) using the following model: deltaTDCO((calc))=-13.15+0.35(deltaVTI*HR)+0.61(deltaSvO(2)) where Delta indicates the percentage change from baseline values. The changes in mean arterial pressure, mean pulmonary artery pressure, and continuous cardiac output did not correlate with the changes in TDCO.
Conclusion:
The use of the VTI*HR, as determined by TEE, in addition to the SvO(2) can strengthen clinical decision making during repositioning and stabilization of the heart during OPCAB. Changes in the VTI*HR and SvO(2) can be used as surrogate markers for changes in CO during OPCAB surgery.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...