Related Experiment Video
Updated: Aug 17, 2026

Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Lack of reproducibility of linkage results in serially measured blood pressure data
Sanjay R Patel1, Juan C Celedon, Scott T Weiss
1Channing Laboratory, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusettes, USA. spatel@partners.org
Background:
Using the longitudinal Framingham Heart Study data on blood pressure, we analyzed the reproducibility of linkage measures from serial cross-sectional surveys of a defined population by performing genome-wide model-free linkage analyses to systolic blood pressure (SBP) and history of hypertension (HTN) measured at five separate time points.
Results:
The heritability of SBP was relatively stable over time, ranging from 11.6 to 23.5% (coefficient of variation = 25.7%). However, the variability in linkage results was much greater. The average correlation in LOD scores at any pair of time points was 0.46 for HTN (NPL All LOD) and 0.17 for SBP (Variance Components LOD). No evidence of reproducible linkage results was found, with a mean kappa of 0.02 for linkage to HTN and -0.03 for SBP linkage. At loci with potential evidence for linkage (LOD > 1.0 at one or more time points), the correlation was even lower. The coefficient of variation at loci with potential evidence of linkage was 126% for HTN and 135% for SBP. None of 15 chromosomal regions for HTN and only one of 28 regions for SBP with potential evidence for linkage had a LOD > 1.0 at more than two of the five time points.
Conclusion:
These data suggest that, although heritability estimates at different time points are relatively robust, the reproducibility of linkage results in serial cross-sectional samples of a geographically defined population at successive time points is poor. This may explain in part the difficulty encountered in replicating linkage studies of complex phenotypes.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
09:18Doppler Ultrasound-Based Leg Blood Flow Assessment During Single-Leg Knee-Extensor Exercise in an Uncontrolled Setting
Published on: December 15, 2023
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure