A fine balance--one-lung ventilation in a patient with Eisenmenger syndrome
1Department of Anaesthesiology and Intensive Care Medicine, University Hospital Carl Gustav Carus, Harvard Medical International Associated Institution, Fetscherstrasse 74, D-01307 Dresden, Germany. axel.heller@mailbox.tu-dresden.de
Abstract:
A 38-yr-old woman with an atrial septum defect and Eisenmenger syndrome was scheduled for a lung biopsy via thoracoscopy during one-lung ventilation. Fluids were given to increase central venous pressure to 8 mm Hg, an epidural catheter was inserted at the sixth thoracic intervertebral space and ropivacaine 0.3%, 6 ml were given. Careful balance of systemic and pulmonary vascular resistance is crucial in Eisenmenger syndrome, so norepinephrine (0.14 mg kg(-1) min(-1)) was infused before general anaesthesia was started with fentanyl 4 mg kg(-1), ketamine 2 mg kg(-1), pancuronium 1 mg and succinylcholine 2 mg kg(-1). Anaesthesia was maintained with propofol 4-8 mg kg(-1) h(-1). To control pulmonary artery pressure, ventilation was performed with oxygen 100% and nitric oxide 20 ppm. Surgery and anaesthesia course were uneventful and the patient was extubated. However, pleural haemorrhage required treatment with blood components, re-intubation on the second postoperative day and removal of the haematoma by mini-thoracotomy. A step-by-step approach using a balanced combination of regional and general anaesthesia, controlled fluid administration, norepinephrine and inhaled nitric oxide preserved a stable circulation even during one-lung ventilation. The diagnostic value of lung biopsy must be weighed against the possibility of life-threatening haemorrhage.
Related Concept Videos
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Atelectasis II: Pathophysiology
Pulmonary Cycle: Exhalation
Acute Respiratory Failure-III
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...