Related Experiment Video
Updated: Aug 19, 2026

Fixed Volume or Fixed Pressure: A Murine Model of Hemorrhagic Shock
Published on: June 6, 2011
Influence of crystalloid and colloid replacement solutions on hemodynamic variables during acute normovolemic
Stephanie B Jones1, Charles W Whitten, Terri G Monk
1Department of Anesthesiology, Washington University School of Medicine, St. Louis, MO, USA. sbjones@bidm.harvard.edu
Study Objective:
To determine whether, in maintaining normovolemia during acute normovolemic hemodilution, replacement fluid choice influences intraoperative hemodynamic variables.
Design:
Prospective, randomized, single-blinded study.
Setting:
Operating room of a tertiary-care university hospital.
Patients:
40 adult, ASA physical status I, II, and III patients scheduled for acute normovolemic hemodilution during radical prostatectomy.
Interventions:
Patients were randomly assigned to four replacement fluid groups to receive 1) Ringer's lactate, 2) 5% albumin, 3) 6% dextran 70, or 4) 6% hetastarch. A standardized general anesthetic was used, and patients underwent moderate hemodilution to a target hemoglobin of 9 gm/dL.
Measurements:
Hemodynamic variables were recorded using standard monitors, 5-lead electrocardiography, radial arterial catheter, and pulmonary artery catheter. Red blood cell loss for the entire hospitalization was calculated.
Main Results:
Demographic and clinical outcome data were similar among the groups. During acute normovolemic hemodilution, heart rate and pulmonary capillary wedge pressure were unchanged from baseline in all groups, but patients receiving Ringer's lactate or albumin had greater declines in mean arterial pressure at the end of acute normovolemic hemodilution. Cardiac and oxygen consumption indexes were stable during acute normovolemic hemodilution, but oxygen extraction increased.
Conclusions:
During hemodilution, anesthetized patients maintain whole body oxygenation by increasing oxygen extraction. The administration of hetastarch or dextran as the replacement fluid during acute normovolemic hemodilution is associated with a more stable mean arterial pressure, but overall acute normovolemic hemodilution is well tolerated irrespective of the replacement fluid used.
Related Concept Videos
Hormonal Regulation of Blood Pressure
Epinephrine and Norepinephrine
The adrenal medulla releases epinephrine and norepinephrine, catecholamines that enhance and extend the sympathetic or "fight or flight" physiological response. These hormones escalate heart rate and the force of contraction while...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Heart Failure II: Pathophysiology
Continuous Renal Replacement Therapy
Acute Kidney Injury V: Interprofessional Care