Multislice CT: technical principles and future trends
1Department of Radiology, University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, The Netherlands. m.prokop@azu.nl
Abstract:
Multislice scanning has substantially improved the performance of CT scanners, and thus the relation between scan duration, available scan length, and spatial resolution along the patient axis (z-axis). Near-isotropic imaging of whole organ systems is already possible with 4-slice scanners, but only with 8- to 16-slice scanners can the scan duration be shortened as well. Reconstructing overlapping thin-section data ("secondary raw data set") provides the basis for image reconstruction in any desired plane. By using thick multiplanar reformation (MPR) techniques, image quality can be improved while keeping patient dose low. Using unfavorable scanning parameters, exposure dose can be substantially increased compared with single-slice scanning, but thick MPR and individual-dose modulation techniques can provide the basis for dose reduction. Low-kVp scanning, in particular, is useful in children and slim adults and is an excellent technique to improve image contrast in CT angiographic studies. Short spiral scans should be avoided with multislice CT since overranging (extra rotations at the beginning and end of the scan, used for data interpolation) can substantially increase patient dose. Future trends include the introduction of thinner detector rows, wider detector arrays, faster tube rotation, and area detectors than can also be used for fluoroscopy. Noise-reduction techniques and individual dose modulation will gain importance with higher isotropic resolution. Functional and perfusion imaging, as well as advanced image processing and computer-aided diagnosis programs, will add to the possibilities of the next generation of multislice CT scanners.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography