Related Experiment Video
Updated: Aug 26, 2026

Surgical Placement of Catheters for Long-term Cardiovascular Exercise Testing in Swine
Published on: February 9, 2016
Effects of intracoronary shunts on coronary endothelial coating in the human beating heart
Herbert B Hangler1, Kristian Pfaller, Elfriede Ruttmann
1Department of Cardiac Surgery, Institute of Anatomy Histology and Embryology, Leopold-Franzens-University, Innsbruck, Austria. herbert.hangler@uibk.ac.at
Insights
Intracoronary shunts cause significant endothelial injury during beating heart surgery, unlike silicone loops. Routine shunt use is discouraged to protect coronary artery health.
Area of Science:
- Cardiovascular Surgery
- Vascular Biology
- Surgical Innovation
Background:
- Beating heart revascularization can damage coronary arteries, particularly the endothelium.
- Understanding the impact of surgical techniques on arterial integrity is crucial.
Purpose of the Study:
- To compare endothelial injury from intracoronary shunts versus silicone loops in human coronary arteries during beating heart surgery.
- To evaluate the effects of these techniques using scanning electron microscopy.
Main Methods:
- Human coronary arteries from heart transplant patients were used (n=12).
- Local occlusion was achieved using either silicone loops or shunts after arteriotomy.
- Scanning electron microscopy assessed endothelial integrity in manipulated and control segments.
Main Results:
- Shunt insertion resulted in statistically significant higher endothelial injury compared to controls and silicone loops (p < 0.001).
- No significant difference in injury was observed between patient groups (dilated cardiomyopathy vs. ischemic heart disease).
Conclusions:
- Intracoronary shunts cause severe endothelial denudation in human coronary arteries during beating heart surgery.
- Selective use of shunts is recommended only when critical ischemia or technical challenges are anticipated.
- Routine shunt insertion should be avoided to preserve coronary artery health.
Background:
Local occlusion of coronary arteries during beating heart revascularization leads to injury of the arterial wall especially disturbing the integrity of the endothelium. The aim of this study was to elucidate the effects of intracoronary shunts versus local occlusion with elastic silicone loops on the beating heart in human coronary arteries by scanning electron microscopy.
Methods:
Coronary arteries of patients with dilated cardiomyopathy (n = 4) or ischemic heart disease (n = 8) undergoing heart transplantation were locally occluded either with a silicone loop or with a shunt inserted after arteriotomy. Unmanipulated segments of the coronary arteries served as controls. Integrity of the endothelial lining was observed with scanning electron microscopy.
Results:
Scanning electron microscopy revealed a statistically significant higher injury after shunting compared with controls (p < 0.001) and vessel loop occlusion (p < 0.001). There was no difference between both patient groups according to control specimens or after manipulation.
Conclusions:
From this investigation we conclude that insertion of intracoronary shunts during beating heart surgery leads to severe endothelial denudation in human coronary arteries. Therefore, at present we recommend using intracoronary shunts selectively in cases in which critical ischemia or technical difficulties as a result of anatomic conditions are expected during anastomosis and avoiding routine shunt insertion into coronary arteries during beating heart revascularization.

