Isotropic half-millimeter angiography of coronary artery bypass grafts with 16-slice computed tomography
Marc Dewey1, Alexander Lembcke, Christian Enzweiler
1Department of Radiology, Charité, Humboldt-University Medical School, Berlin, Germany. marc.dewey@charite.de
Background:
Computed tomography (CT) with four detector rows and magnetic resonance imaging (MRI) are still of limited value for the assessment of coronary artery bypass grafts (CABG). We investigated the abilities of 16-slice CT in these patients.
Methods:
A retrospective analysis of all noninvasive coronary angiographies with multislice computed tomography (MSCT; Aquilion, Toshiba) on patients with CABG referred to our institution between October 2002 and April 2003 was conducted. MSCT angiography was performed using a standard protocol (0.5-seconds rotation time, 16 x 0.5 mm detector collimation, 120 kV, 250 to 300 mA, and 0.25 pitch). None of the patients received beta-blockers to reduce the heart rate. Seventy-five CABGs (20 arterial grafts and 55 venous grafts) in 27 patients were evaluated for patency and adequate diagnostic quality by two radiologists in consensus.
Results:
All arterial and venous grafts were depicted with adequate diagnostic quality and were eligible for evaluation. Fifteen occlusions and five significant stenoses (at least 50%) could be identified. All of the proximal and 99% of the distal anastomoses were eligible. One distal anastomosis of an arterial graft was not assessable due to surgical clip artifacts. The length of the acquisition window was 174 +/- 46 ms (range 71 to 234 ms). The majority of the patients (70%) had a heart rate above 65 beats/min. However, due to the improved temporal and spatial resolution none of the examinations had an insufficient image quality.
Conclusions:
MSCT angiography with 16 detector rows and an isotropic high resolution reliably depicts CABG with adequate diagnostic quality.
More Related Videos
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...