Simultaneous assessment of diameter and pressure waveforms in the carotid artery
Jan M Meinders1, Arnold P G Hoeks
1Department of Biophysics, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands. j.meinders@bf.unimaas.nl
Abstract:
Simultaneous assessment of diameter and pressure waveforms allows the calculation of the incremental compliance, distensibility, pulse wave velocity and elastic modulus as function of the distending pressure. However, the waveforms must be obtained at the same position and acquired and processed with the same filter characteristics to circumvent possible temporal and spatial changes in amplitude and phase. In this paper, arterial diameter waveforms are assessed by means of ultrasound (US) and converted to pressure using an empirically derived exponential relationship between pressure and arterial cross-section. The derived pressure waveform is calibrated to brachial end diastolic and mean arterial pressure by iteratively changing the wall rigidity coefficient (i.e., the exponential power). Because pressure is derived directly from arterial cross-section, no phase delay is introduced due to spatial separation or different filter characteristics. The method was evaluated for the left common carotid artery of 51 healthy subjects ranging in age from 22 to 75 years old. In healthy subjects, the carotid pulse pressure is 29% lower than the brachial pulse pressure. Continuous assessment of arterial properties confirms that pulse-wave velocity and incremental elastic modulus increase, whereas distensibility and compliance decrease, as function of increasing distending blood pressure.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: