Related Experiment Video
Updated: Aug 26, 2026

Identification and Protection of the Recurrent Laryngeal Nerve during Transoral Robotic Thyroidectomy
Published on: October 24, 2025
Unnecessary laryngeal irradiation in the IMRT era
Robert J Amdur1, Jonathan G Li, Chihray Liu
1Department of Radiation Oncology, University of Florida Health Science Center, P.O. Box 100385, Gainesville, Florida 32610-0385, USA. amdurrj@shands.ufl.edu
Purpose:
The purpose of this review is to address the issue of unnecessary irradiation of the normal larynx.
Methods:
We performed a literature review and dosimetry evaluation of intensity modulated radiotheraphy (IMRT) techniques.
Results:
Data suggest that matching conventional parallel opposed photon fields through adenopathy is a reasonable alternative to the common practice of unnecessarily irradiating the normal larynx to high doses. The dosimetry evaluation demonstrates that the laryngeal dose is much higher when the entire neck is included in the IMRT field as opposed to using a standard anterior low-neck field below the level of the thyroid notch.
Conclusions:
Lateral opposed fields should not be extended to include the larynx to avoid matching fields through adenopathy. IMRT fields should not include the normal larynx when the laryngeal dose would be substantially lower with a technique that shields the larynx in an anterior low-neck field.