Verification of Ir-192 near source dosimetry using GAFCHROMIC film
Sou-Tung Chiu-Tsao1, Tamara L Duckworth, Neil S Patel
1Department of Radiation Oncology, Beth Israel Medical Center and St. Luke's-Roosevelt Hospital Center, New York, New York 10003, USA. schiutsa@bethisraelny.org
Abstract:
Intravascular brachytherapy treatments of in-stent restenosis have been performed extensively using Ir-192 ribbon. Task Group 60 of the American Association of Physicists in Medicine (AAPM) recommends a dose reference point at 2 mm from the source center for these treatments. However, it is known that the source can be as close as 0.5 mm to the arterial wall if not centered in the lumen. Therefore, the source dosimetry needs to be characterized at these close distances to accurately determine the amount of dose delivered for noncentered cases. In this paper, we report the verification of the dose distributions around Ir-192 seed sources at radial distances from 0.5 mm to 6 mm using GAFCHROMIC film. We evaluated an Ir-192 single seed source and a train of 6 seeds spaced 1 mm apart enclosed in a nylon ribbon. Each source was placed in a homogeneous solid water phantom directly below a stack of GAFCHROMIC films (MD-55-2). The calibration curve of the lot of films used in the experiment was established for Ir-192 by exposing a set of calibration films, one at a time, to an Ir-192 high dose rate (HDR) source. All films were scanned 5 or more days after exposure with a Lumisys Model 150 microdensitometer. The data were acquired and evaluated using RIT113 (Radiological Imaging Technology) software and analyzed using Excel and IDL (Interactive Data Language) software. Isodose curve plots in the plane containing the source's longitudinal axis and dose rate plots in the radial direction were obtained. For both configurations, the dose rates along the transverse axes agree to within the margin of error with previous Monte Carlo results. The isodose curve plots display hot spots near the seed ends, which is consistent with the leakage of beta particles and electrons from the unsealed seed ends as predicted with Monte Carlo calculations.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017