Related Experiment Video
Updated: Aug 17, 2026

Delivery of In Vivo Acute Intermittent Hypoxia in Neonatal Rodents to Prime Subventricular Zone-derived Neural Progenitor Cell Cultures
Published on: November 2, 2015
Validation of pulse oximetry during progressive normobaric hypoxia utilizing a portable chamber
Jon C Kolb1, Peter Farran, Stephen R Norris
1Faculty of Kinesiology, Univ. of Calgary, Canada.
Abstract:
Validation of pulse oximetry in commercially available normobaric hypoxic chambers (NHC) has not been previously reported. The present study examined the validity of pulse oximetry (SpO2) against direct measurements of arterial oxygen saturation (SaO2) via co-oximetry (AVOXimeter 4000) in 13 young adults age 21.3 +/- 0.6 years. Over a period of 2.5 hrs, the inspired fraction of oxygen inside a NHC (Hypoxico, Inc.) was progressively reduced from 20.9% to 11.5%. Measurements of SaO2 at baseline and at 15, 30, 60, 90, 120, and 150 min during the hypoxic exposures were compared with SpO2 estimates of oxygen saturation (Nellcor 295) using reflectance (RS-10, temporal) and transmission (D-25, finger) sensors. Regression analysis and methods for assessing agreement (bias, b; precision, p) of SaO2 with SpO2 were similar (R2 = 0.92, 0.89; b = 0.016, -0.47; p = 2.47, 3.03; RS-10 and D-25, respectively). When SaO2 < 85%, RS-10 had greater validity than D-25 (R2 = 0.73, 0.56; b = 1.38, 1.13; p = 2.72, 4.34; RS-10 and D-25, respectively). In light of these findings, caution should be exercised when monitoring individuals with pulse oximetry during desaturation episodes below 85%. When employing frequent NHC exposures, a priori validation of SpO2 utilized to assess blood oxygen status appears warranted.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

