Comparing ocular muscle limitation tests for clinical trial use
Mark J Kupersmith1, Hilary E Fazzone
1Institute for Neurology and Neurosurgery at Beth Israel Medical Center and New York Eye and Ear Infirmary, New York, USA. mkuper@bethisraelny.org
Archives of Ophthalmology (Chicago, Ill. : 1960)
|March 10, 2004
Summary
Portable ocular muscle testing methods, including the Kestenbaum test and a cervical range of motion (CROM) device, show good repeatability for clinical trials. A simple grading scale also demonstrated consistent results between examiners.
Area of Science:
- Ophthalmology
- Clinical Trials
- Neurology
Background:
- Ocular muscle limitation assessment is crucial for diagnosing and monitoring various neurological and ophthalmological conditions.
- Standardized and portable methods are needed for multi-site clinical trials to ensure consistent data collection.
- Existing methods for documenting ocular muscle limitation vary in precision and portability.
Purpose of the Study:
- To evaluate the reliability and repeatability of portable methods for documenting ocular muscle limitation in a clinical trial setting.
- To compare a clinical grading scale, the Kestenbaum limbus test, and an adapted cervical range of motion (CROM) device for ocular duction testing.
Main Methods:
- A prospective case series involving 2 independent examiners evaluating 20 patients with diplopia.
- Methods assessed included a 0 to -5 grading scale, Kestenbaum test (measuring in millimeters), and CROM device (measuring in degrees).
- Patients had conditions such as ocular myasthenia gravis, cranial nerve palsies, and dysthyroid ophthalmopathy.
Main Results:
- The Kestenbaum test showed good inter-examiner repeatability with 95% of differences within 4 mm.
- The CROM device demonstrated high intra-examiner repeatability (differences < 2 degrees) but moderate inter-examiner repeatability (95% within 15 degrees).
- The clinical grading scale achieved identical scores between examiners in 85% of ductions.
Conclusions:
- The Kestenbaum test and CROM device offer comparable inter-examiner repeatability for ocular muscle limitation.
- While CROM device measurements are highly consistent within an examiner, inter-examiner consistency is less robust.
- The clinical grading scale provides reliable and consistent results between examiners, making it a viable option for multi-site trials.