Enhanced coronary flow velocity during intra-aortic balloon pumping assessed by transthoracic Doppler
Masaaki Takeuchi1, Yuichi Nohtomi, Hidetoshi Yoshitani
1Department of Internal Medicine, Tane General Hospital, 1-2-31 Sakaigawa, Nishi-ku, Osaka 500-0024, Japan. masaaki_takeuchi@hotmail.com
Objectives:
The study was done to determine potential utility of measuring coronary flow velocity (CFV) by transthoracic Doppler echocardiography (TTDE) during intra-aortic balloon pumping (IABP).
Background:
Use of IABP has been shown to increase CFV assessed by an invasive technique. The CFV in the left anterior descending coronary artery (LAD) can be measured by TTDE.
Methods:
Coronary flow velocity in the distal LAD by TTDE was measured in 40 critically ill patients requiring IABP. All patients received emergency coronary angiography. Both CFV and pressure data were obtained during 1:2 balloon pumping.
Results:
Adequate diastolic CFV recording was obtained in all patients. The IABP decreased systolic pressure and increased diastolic pressure. Average peak diastolic flow velocity and diastolic velocity time integral was 19 +/- 11 cm/s and 7.7 +/- 4.4 cm with non-augmented beat. These values were increased significantly (61 +/- 38%, 59 +/- 35%, p < 0.001) with augmented beat. Significant correlation was noted between % diastolic pressure augmentation and % increase in diastolic CFV (r = 0.62 to 0.69, p < 0.001). There was no significant difference in flow enhancement during IABP, irrespective to the proximal LAD stenosis severity (severe stenosis: 73 +/- 70%; intermediate stenosis: 61 +/- 29%; no significant stenosis: 58 +/- 29%; p = NS, analysis of variance). By continuous recording of CFV, the optimal timing of balloon control could be adjusted to maximize flow velocity during augmentation.
Conclusions:
Use of TTDE can be employed in monitoring CFV augmentation during IABP. The IABP produced significant distal flow enhancement even in patients with critical proximal stenosis. This totally noninvasive approach may help to optimize the benefits of IABP for coronary flow augmentation.
Related Concept Videos
Velocity and Acceleration in Steady and Unsteady Flow
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Doppler Effect - I
Doppler Effect - II
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...