Related Experiment Video
Updated: Aug 4, 2026

3D Planning and Printing of Patient Specific Implants for Reconstruction of Bony Defects
Published on: August 4, 2020
Immediate Dental Implant Placement in Sockets Augmented With HTR Synthetic Bone
Paulino Castellon1, Raymond A Yukna
1Department of Prosthodontics, Louisiana State University School, New Orleans, 70119, USA. pcaste@lsuhsc.edu
Purpose:
The purpose of this article is to present the results of using immediate implant placement in combination with HTR synthetic bone socket grafting to achieve a predictable restorative result.
Material And Methods:
Twenty-three hydroxylapatite-coated cylinder implants (Spline, CenterPulse Dental, Carlsbad, CA) were placed into fresh extraction sockets in 19 patients. In each case, HTR synthetic bone (Bioplant, Inc., South Norwalk, CT) was used to fill any voids remaining in the sockets and to augment the facial aspect of the ridge. The restorative phase was initiated approximately 6 months after implant placement. Conventional impression techniques were used and porcelain-fused-to-metal crowns were selected as the final restorations.
Results:
The prosthetic outcome was evaluated as generally favorable. Only 4 (17%) of the dental implants required an angled abutment. The gingival contour was excellent in 61% and good in 35% of the cases. The emergence profile was evaluated as class I (full papilla) in 37% and class II, III, and IV in 21% each.
Conclusions:
The clinical results of this study demonstrate that immediate implant placement in combination with HTR synthetic bone grafting of residual socket voids and crestal deformities is a predictable procedure and provides a good base for successful prosthetic reconstruction. Adequate gingival contour and favorable emergence profile can be expected when combining immediate implant placement and HTR grafting material.