Induction of Adhesion-dependent Signals Using Low-intensity Ultrasound
Published on: May 8, 2012
Ultrasonic deposition of cells on a surface
Jeremy J Hawkes1, Michael J Long, W Terence Coakley
1Department of Instrumentation and Analytical Science, UMIST, P.O. Box 88, Manchester M60 1QD, UK. j.hawkes@umist.ac.uk
Abstract:
Bacteria in water have been driven to a glass surface by an ultrasonic standing wave. On an antibody coated surface capture of Bacillus subtilis var niger (BG) spores (6.6 x 10(6) ml(-1)) was increased more than 200-fold over above the efficiency in the absence of ultrasound. In microfluidic (non-turbulent) systems detection of particles by sensors operating at a surface is diffusion limited. This results in very low detection abilities particularly for particles with diameters greater than 1 microm. Ultrasound is used here to drive bacterial spores to a wall and overcome this limitation. The results confirm: (1) pressure nodes can be formed close to the water-glass interface when the glass thickness is near half the ultrasonic wavelength; (2) the antibody used was able to capture spores in the presence of an ultrasonic standing wave.