Endothelialized Microfluidics for Studying Microvascular Interactions in Hematologic Diseases
Published on: June 22, 2012
The construction of endothelial cellular biosensing system for the control of blood pressure drugs
Ken-ichiro Kamei1, Tetsuya Haruyama, Masayasu Mie
1Department of Biological Information, Graduate School of Bioscience and Biotechnology, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-8501, Japan.
Abstract:
In order to assess blood pressure control drugs, the endothelial cellular biosensing system for assessing blood pressure control drugs was constructed. This system consists of human umbilical vein endothelial cells (HUVEC) on a polyion-coated gold electrode, a platinum counter electrode and an Ag/AgCl reference electrode. Nitric oxide (NO) as an indicator of blood vessel relaxation was detected with a polyion-coated electrode in the system. The NO detection limit of this electrode was 8.4 nM by differential pulse voltammetry (DPV). The drugs of blood pressure control (acetylcholine chloride (AcChCl), NOC 7 and NG-monomethyl-L-arginine (L-NMMA)) were assessed with this endothelial cellular biosensing system. One milli molar of AcChCl make NO released from HUVEC stimulated by activating endothelial nitric oxide synthase (eNOS) in HUVEC. In the case of 5 mM of L-NMMA, NO releasing was inhibited by inhibiting eNOS activation by 1 mM of AcChCl. NOC 7 immediately released NO regardless of eNOS activation in endothelial cells.
More Related Videos
10:51Fabrication and Validation of an Organ-on-chip System with Integrated Electrodes to Directly Quantify Transendothelial Electrical Resistance
Published on: September 26, 2017
14:10A Microfluidic System for Modeling Endothelial Dysfunction under Combined Physiological Pulsatile Shear Stress and Oscillatory Hyperglycemia
Published on: May 12, 2026
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: