Related Experiment Video
Updated: Aug 25, 2026

Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Analysis of unknown organic pollutants in sewage by solid-phase extraction combined with gas chromatography-mass
Hong Gao1, Ting Zhao, Qin Kong
1Department of Chemistry, Lanzhou University, Lanzhou 730000, P.R. China.
Abstract:
A rapid, simple, and reliable method of solid-phase extraction (SPE) combined with gas chromatography (GC)-mass spectrometry (MS) is developed for the analysis of a wide range of polarity of unknown organic pollutants in sewage. Wastewater samples are extracted by passing them through disposable C(18) cartridges, and the extracts are then analyzed by GC-MS. Different SPE parameters for ten organic compounds in the list of priority pollutants suggested by the China Environmental Protection Agency (EPA) are studied, and their breakthrough volumes are determined. Extraction recoveries for the tested compounds are greater than 60%, except the recovery of 1,2-dichloroethane is 48%. The relative standard deviations are less than 7.8% (n = 3). The developed approach is successfully applied for the identification of organic components in a sewage sample. Over 220 organic pollutants are identified, with 5 of these present in the list of priority pollutants suggested by the U.S. EPA and 4 from the list by the China EPA.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...

