[Extreme results in electrolyte determination]
1Institut für Klinische Chemie und Laboratoriumsmedizin, Deutsches Herzzentrum München des Freistaates Bayern, Bundesrepublik Deutschland.
Abstract:
Besides statistical quality control, quality control based on patient specimens is an important tool for quality enhancement and thus for an increased diagnostic certainty in laboratory medicine. One of three possibilities of plausibility judgement is the control of extreme results, that is alert and absurd value check. The aim of our study was to look for extremely high or low findings of the most frequently examined clinical-chemical parameters, to scrutinize their validity according to clearly defined criteria and to find out the underlying actual clinical situations and diseases. In this publication only the results for the electrolytes are discussed. Retrospectively the most extreme values of all results for serum sodium, potassium and chloride concentrations of a 21-month interval were extracted in a large university hospital. The clinical situation was then evaluated by reading the medical reports of these patients. The validity of the findings was judged by previously defined criteria and rated as confirmed, questionable and not confirmed. In all cases the survival time was determined. The most extreme confirmed results were for sodium 191 and 100 mmol/l, for potassium 9.0 and 1.3 mmol/l and for chloride 138 and 65 mmol/l. All these findings were compatible with life, at least for several hours. Even if it is probably impossible to give generally valid extreme ranges. Nevertheless our results should certainly have practical importance in absurd and alert value check.
More Related Videos
Related Concept Videos
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in the...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Theory of Strong Electrolytes